- Published on
We wish you all a Merry Christmas and a prosperous New Year.
- Published on
PRESSURISED LABORATORY CABIN, PRESSURISED WORKSHOP CONTAINER, MUD LOGGING UNIT, MUD LOGGING CABIN, PRESSURISED MODULES, OFFSHORE PRESSURISED MODULES
DNV 2.7-1, A60 Fire Rated and Zone I / zone II
Flexible and customised dimension and layout, 10ft/12ft/15ft/16ft/20ft/26ft/40ft etc
Lead time: 3-4 months.
which includes:
Engineering : Structural drawings, Architectural drawings and Documentation package c/w as built drawings and Certifications (CSC certificate, DNV2.7-1/EN12079 certificate, A60/Zone 1/Zone 2 certificate of conformity).
Fabrication : Structural materials to DNV 2.7-1 and A60 fire rated specification, Welding procedures, Welding inspections and Secondary steel provisions.
Assembly : 1 x A60 Main door, 1 x A60 Escape hatch, A60 Thermal Insulation, 1 x B15 Airlock Door w/ viewing glass, self- fabricated internal panel for wall, ceiling and airlock compartment.
Testing and Inspection: MPI and load testing in accordance with DNV 2.7-1, A60 insulation certification by DNV and Factory Acceptance Test (FAT) , Pressurised, Fire and Gas System,
Electrical Work : Lighting and small power Distribution Board(DB) c/w circuit breakers, Cabling within Laboratory unit for lighting and power points, Conduit wiring for lightings, Trunking wiring for 220V, 8 x Double gang 230V 13A switch socket (Non-Ex), 3 x IP rated 2x36W fluorescent lighting, 1 x Non Ex rated light switch, MCT frames c/w MCT inserts, Earth bosses, 1 x Exe PJB at recessed area.
Safety Equipment : Purge, Pressurized, Fire and Gas Control Panel, 2 x CH4 Detector, 1 x H2S Detector, 1 x Smoke Detector, 1 x Heat Detector, Pressure Switches and gauge, 1 x Ex Loss of Pressure Alarm, A60 Shutdown dampers, 1 x Emergency Lightings, 1 x Emergency Shut-down Button, 1 x Ex-proof Pressurisation Blower set & 1 x DNV 2.7-1 compliance lifting sling set.
Air Conditioning System: 1 set 14,000BTU Split System c/w indoor evaporator set, indoor compressor set, indoor aircon circuitry box, outdoor copper condenser coil in stainless steel housing & Ex condenser motor.
(20ft cabin)
Air Conditioning System: 2 set 14,000BTU Split System c/w indoor evaporator set, indoor compressor set, indoor aircon circuitry box, outdoor copper condenser coil in stainless steel housing & Ex condenser motor.
(40ft cabin)
Furnishing : N.A.
Painting Work : Preparation : Blasting to S.A. 2.5, Painting System : Three (3) coat System of 1st coat (65micron) with zinc rich epoxy primer, 2nd coat (75micron) with red lead epoxy primer, final coat (50micron) with Polyurethane coat.
Please download Pressurised cabin product brochure for reference.
Please don't hesitate to contact us at sales@tls-containers.com for any inquiries.
DNV 2.7-1, A60 Fire Rated and Zone I / zone II
Flexible and customised dimension and layout, 10ft/12ft/15ft/16ft/20ft/26ft/40ft etc
Lead time: 3-4 months.
which includes:
Engineering : Structural drawings, Architectural drawings and Documentation package c/w as built drawings and Certifications (CSC certificate, DNV2.7-1/EN12079 certificate, A60/Zone 1/Zone 2 certificate of conformity).
Fabrication : Structural materials to DNV 2.7-1 and A60 fire rated specification, Welding procedures, Welding inspections and Secondary steel provisions.
Assembly : 1 x A60 Main door, 1 x A60 Escape hatch, A60 Thermal Insulation, 1 x B15 Airlock Door w/ viewing glass, self- fabricated internal panel for wall, ceiling and airlock compartment.
Testing and Inspection: MPI and load testing in accordance with DNV 2.7-1, A60 insulation certification by DNV and Factory Acceptance Test (FAT) , Pressurised, Fire and Gas System,
Electrical Work : Lighting and small power Distribution Board(DB) c/w circuit breakers, Cabling within Laboratory unit for lighting and power points, Conduit wiring for lightings, Trunking wiring for 220V, 8 x Double gang 230V 13A switch socket (Non-Ex), 3 x IP rated 2x36W fluorescent lighting, 1 x Non Ex rated light switch, MCT frames c/w MCT inserts, Earth bosses, 1 x Exe PJB at recessed area.
Safety Equipment : Purge, Pressurized, Fire and Gas Control Panel, 2 x CH4 Detector, 1 x H2S Detector, 1 x Smoke Detector, 1 x Heat Detector, Pressure Switches and gauge, 1 x Ex Loss of Pressure Alarm, A60 Shutdown dampers, 1 x Emergency Lightings, 1 x Emergency Shut-down Button, 1 x Ex-proof Pressurisation Blower set & 1 x DNV 2.7-1 compliance lifting sling set.
Air Conditioning System: 1 set 14,000BTU Split System c/w indoor evaporator set, indoor compressor set, indoor aircon circuitry box, outdoor copper condenser coil in stainless steel housing & Ex condenser motor.
(20ft cabin)
Air Conditioning System: 2 set 14,000BTU Split System c/w indoor evaporator set, indoor compressor set, indoor aircon circuitry box, outdoor copper condenser coil in stainless steel housing & Ex condenser motor.
(40ft cabin)
Furnishing : N.A.
Painting Work : Preparation : Blasting to S.A. 2.5, Painting System : Three (3) coat System of 1st coat (65micron) with zinc rich epoxy primer, 2nd coat (75micron) with red lead epoxy primer, final coat (50micron) with Polyurethane coat.
Please download Pressurised cabin product brochure for reference.
Please don't hesitate to contact us at sales@tls-containers.com for any inquiries.
PRESSURISED LABORATORY CABIN, PRESSURISED WORKSHOP CONTAINER, MUD LOGGING UNIT, MUD LOGGING CABIN
- Published on
40 foot Containerized Filling/fueling station with safe fill level of approx. 67,000 litres.
STANDARD FITTINGS: 80 nb Camlock male tanker hose filler with dust cap connect, Tanker full point supplied with 80nb full bore, fire safe flanged ball valve and wafer style non return valve, container corner castings, statutory access manway, permanent ladder and platform, water evacuation pipe, interstitial space fluid dipstick, containment compartment with pressure vent, marine grade polyurethane paint
STANDARD FITTINGS: 80 nb Camlock male tanker hose filler with dust cap connect, Tanker full point supplied with 80nb full bore, fire safe flanged ball valve and wafer style non return valve, container corner castings, statutory access manway, permanent ladder and platform, water evacuation pipe, interstitial space fluid dipstick, containment compartment with pressure vent, marine grade polyurethane paint
- Safe fill level of approx. 67,000 ltrs.
- Weight Bare Tank (lbs/kg): 24692 lbs (11200kg)
- Approx. size of the unit: Length 1218 millimeters / width 2438 millimeters / Height 2896 millimeters. With Bunded Double wall construction with a pump bay area.
- Built to ISO container standard.
- Pump Bay Area to include:
- A single high flow dispenser.
- 2hp red jacket submersible turbine pump.
- Mechanical overfill device.
- OPW mechanical level gauge
- Fuel piping
- Offloading point, camlock coupling with ball & check value.
- Explosion proof control panel & lighting.
- Smart fill fuel automation system with online & remote access.
- Tank Gauging System. (Tank Gauging console, Mag prove, Leak detection sensors)
- Published on
TLS provides standard or customized helicopter fuel tanks (helifuel tank) to safely transport and store aviation fuel. Our design is well integrated into the design of helicopter fuel distribution systems. The helifuel tank is equipped with a vapor recovery system, which is in compliance with DNV 2.7-1 / EN 12079, IMDG/ADR/RID, ASME VIII-1, PED 97/23/EC (CE marking) and CAP 437 (UK ) And CAAP 92-4 (Australia).
Features:
Please don't hesitate to contact us at sales@tls-containers.com for more information.
Features:
- Storage of jet propulsion fuels such as kerosene
- DNV 2.7-1 / EN 12079 manufacturing standards
- T7 UN portable tank approved IMDG / ADR / RID
- Placarded for road transport in accordance with the IMDG code where required
- 2.67 bar working pressure
- Discharge 2.5' Dry-break
- Valve 1½" BSP
- Remote vent valve and level indicator (optional)
- Vessel material – 316L stainless steel
Please don't hesitate to contact us at sales@tls-containers.com for more information.
- Published on
- Living module | cabin | quarter
- Accommodation container | cabin | module
- Mess module | Gallery module
- Office module | container
- Shower module | container
- GYM module | container
- Prefabricated Prefinished Volumetric Construction (PPVC) module
TLS customizes ranges of offshore accommodation cabins / living quarter / living cabins according to client's specific requirement.
Please don't hesitate to contact us at sales@tls-containers.com if you have any inquires.
- Published on
A MUD logging unit is installed on the rig when geologic information must be retrieved on a timely basis. If the formations drilled are not well known or if a specific geologic horizon is targeted, mineralogical data from cuttings brought to the surface with the mud might be essential. MUD logging units can discover and evaluate oil & gas reservoirs rapidly, provide complete drilling parameters and monitor toxic gases, thus ensuring drilling safety, enhancing drilling efficiency and reducing operation cost.
As mud logging units are normally located in the hazardous zone 1 or zone 2, where fire or explosion hazards may exist, and the all the measurement equipment installed inside the mud logging units are not explosion proof, therefore the mud logging units should be positively pressurized by blowing fresh air without flammable gases, which creates a safe working environment not only for electric equipment inside, but also for mud loggers and working personnel.
Our explosion proof and intelligent pressurized containers are designed to meet the requirement of clients, suitable for onshore or offshore drilling, A0 or A60 fire rated. Intelligent pressurized containers are equipped with CPFG (combined pressurization, fire and gas control panels), gas detectors, pressurization fan, fire dampers, etc, which is suitable to be used as mud logging cabin.
TLS provides intelligent pressurized containers to global clients for many years. The pressurized container dimension and specifications can be customized according to client’s requirement.
Main Features:
1.Positive Pressure & Explosion-Proof Container
2.Wireless data acquisition system
3. SGC-3K Multicomponent Chromatograph
4.SL-IR-II CO2 Analyzer
5.SL-SAS Safety Alarm System
6.CVD Constant Volume Degasser
7.SS - 3 mud logging Software System
Please don’t hesitate to contact us at sales@tls-containers.com if you have the requirement.
As mud logging units are normally located in the hazardous zone 1 or zone 2, where fire or explosion hazards may exist, and the all the measurement equipment installed inside the mud logging units are not explosion proof, therefore the mud logging units should be positively pressurized by blowing fresh air without flammable gases, which creates a safe working environment not only for electric equipment inside, but also for mud loggers and working personnel.
Our explosion proof and intelligent pressurized containers are designed to meet the requirement of clients, suitable for onshore or offshore drilling, A0 or A60 fire rated. Intelligent pressurized containers are equipped with CPFG (combined pressurization, fire and gas control panels), gas detectors, pressurization fan, fire dampers, etc, which is suitable to be used as mud logging cabin.
TLS provides intelligent pressurized containers to global clients for many years. The pressurized container dimension and specifications can be customized according to client’s requirement.
Main Features:
1.Positive Pressure & Explosion-Proof Container
- Positive Pressure & Explosion-Proof with DNV 2.7-1 certificate.
- In compliance with IEC 60079-13 Standard
- A60 level fire-proof certificate
2.Wireless data acquisition system
- Explosion-proof design with IP67 protectionOver-current, over-voltage & short circuit protection
- Low-power consumption, can work continuously for at least 20 days with a single charge
- Communication distance: more than 300m
- WITS protocol, compatible with various kinds of mud logging units
3. SGC-3K Multicomponent Chromatograph
- Rapid online analysis of 12 kinds of hydrocarbon component.
- Gas in and gas out, elimination the influence of background gas
- Constant volume degassor
- Detection components: C1-C8 ,benzene, toluene & TG.
- Minimum detectable concentration: 10ppm
- Shortest analytical cycle: 90s(C1- C8)
4.SL-IR-II CO2 Analyzer
- Based on infrared absorption principle
- Detection range:0.2%~100%
- Response time :≤10s
- Detection deviation:±2%FS
- Drifting zero:±2.5%FSRepeatable deviation :<2%
5.SL-SAS Safety Alarm System
- Automatic audio-visual alarm for any parameters
- Effectively prevent drilling accidents
- Anti-explosion & protection level: Exd Ⅱ CT6, IP66
6.CVD Constant Volume Degasser
- Extraction amount of drilling fluid : ≥30.5L / min
- Measurement deviation of supplemental air : 1%
- Adjustable temperature range for heating drilling fluid : 0-140 ℃
- Degassing efficiency: ≥90%
7.SS - 3 mud logging Software System
- Open frame structure
- Real-time formation pressure detection system
- Web publishing system for real-time data on wellsite
- Gas detection & correction software
- Remote online acquisition system
Please don’t hesitate to contact us at sales@tls-containers.com if you have the requirement.
- Published on
Fight against COVID-19, Deep freeze container solutions for transport, storage and distribution COVID-19 vaccines.
Vaccine manufacturers, transportation and storage providers face major challenges in the fight against the coronavirus, because according to the current state of science, many of these vaccines only work at temperatures as low as -80°C / -112°F Maintain its effectiveness.
TLS developed ultra-cold freezer containers with temperatures as low as -80°C / -112°F. This deep freeze container solution can freeze vaccines directly at the manufacturer's factory. For this reason, the cold storage system is located near the production, and the refrigerated container is set outside the production building. Immediately after production, the vaccine is deep-frozen in the refrigerator. This cold storage solution can be installed anywhere that can be used for deep-cooled vaccines. Since the freezing container is based on active deep freezing technology, it does not require dry ice for cooling, which also makes it suitable for safe international air transportation.
Please contact sales@tls-containers.com if you need urgently.
- Deep-frozen container solution for ultra-cold transportation and storage of COVID-19 vaccine
- Transport and store up to 1,000,000 doses of vaccine in standard size containers at ultra-cold temperatures as low as -80°C / -112°F
- Active deep cooling technology ensures safe and controlled transportation and storage without the need for dry ice
Vaccine manufacturers, transportation and storage providers face major challenges in the fight against the coronavirus, because according to the current state of science, many of these vaccines only work at temperatures as low as -80°C / -112°F Maintain its effectiveness.
TLS developed ultra-cold freezer containers with temperatures as low as -80°C / -112°F. This deep freeze container solution can freeze vaccines directly at the manufacturer's factory. For this reason, the cold storage system is located near the production, and the refrigerated container is set outside the production building. Immediately after production, the vaccine is deep-frozen in the refrigerator. This cold storage solution can be installed anywhere that can be used for deep-cooled vaccines. Since the freezing container is based on active deep freezing technology, it does not require dry ice for cooling, which also makes it suitable for safe international air transportation.
Please contact sales@tls-containers.com if you need urgently.
Deep freeze container with temperature down to -80°C / -112 °F for ultra-cold transport and storage for COVID-19 vaccines
Deep freeze container with temperature down to -80°C / -112 °F for ultra-cold transport and storage for COVID-19 vaccines
- Published on
Such explosion proof container provides an adaptable workspace for a multitude of applications such as
Certifications:
Standard Features
- Welding workshop
- Electrical workshop
- Mechanical workshop
- Testing workshop
- Rigging loft
- Storage of goods, tools & materials
Certifications:
- DNV 2.7-1 / BS EN 12079, offshore standard
- CSC Plated
Standard Features
- EX proof electrics, lighting and heating for hazardous zones (zone 1, zone 2)
- Ex proof DBs, air-conditioner
- Ex proof sockets
- Removable workbench, vice and caged shelving
- Anti-slip flooring
- Personnel door, windows
- ISO corner castings
- Forklift pockets
- Lifting pad-eyes, slings and shackles
- Customised features according to specific requirement
- Published on
Every funtional container is customised according to client's specific requirement. TLS is driven by the passion for being a global leading supplier of containerised solutions, TLS does the best to deliver the most premium quality product and service to our clients cost competitively and efficiently.
TLS has a container manufacturing base with 150,000 square meters located in China, which allows TLS to provide the most cost-effective and the complete containerised solutions to worldwide clients.
TLS provides ranges of containerised solutions including intelligent pressurised cabins, temporary refuge shelters, BESS containers, water treatment plant containers, etc.
TLS has a container manufacturing base with 150,000 square meters located in China, which allows TLS to provide the most cost-effective and the complete containerised solutions to worldwide clients.
TLS provides ranges of containerised solutions including intelligent pressurised cabins, temporary refuge shelters, BESS containers, water treatment plant containers, etc.