20 ft laboratory container rated for Safe zone (negative pressure)
Internal Fitment:
Electrical:
Air conditioning
Applicable Codes and Standards
- standard 20 ft HC container dimensions (6058*2438*2896mm)
- Lifting points: 4pcs recessed pad eyes
- Recess: full height recess for Air-con compressor and electrical penetrations
- A60 walls, ceiling and flooring
- Water inlet / outlet connection
- Compressed air connection
- With ventilation system to renew air in the laboratory 6 times per hour in normal operation and 20 times per hour in case of emergency
Internal Fitment:
- Workbenches - (anti-acid material) including drawers cabinet
- Overhead cabinet
- Eyewash
- Fume hood - Ex type (with Ex exhaust fan, Ex lighting, Ex switch, Ex sockets)
- Fire detection system (including heat detector and smoke detector)
- Gas detection CH4 and H2S
- Compressed air connection and Nitrogen connection
- Portable fire extinguisher
Electrical:
- Electrical supply external supply system designed for Safe Area.
- Electrical equipment inside the laboratory to be rated explosion proof
- Control panel - Ex type (automatically response when fire, smoke, toxic gas or flammable gas occur)
- Ex Lighting - 3 pcs (1pc emergency light with battery, Ex-type)
- Ex sockets (220V 3 PIN European style), 5 pcs
- MCT (1 pc, Roxtec)
- Emergency shutdown - Ex type
- Exhaust fans (1pc installed inside fume hood, 1pc installed outside) - Ex type
- Phone and network cabling
Air conditioning
- One Split Type AC unit - Ex Type (working temperature -20°C / +50°C, T3), 24000BTU
Applicable Codes and Standards
- Bureau Veritas or other major IACS Classification Societies
- Published on
- Published on
- Published on
TLS temporary refuge equipped with independent gas supply system, when gas pollution occurs outside, a gas circulation system is formed inside TR, which effectively protects internal personnel from toxic gas hazards.
The compressed air bottle is used as the source of breathing gas to ensure the normal breathing of internal personnel while maintaining a slight positive pressure inside, which can effectively prevent toxic gas from entering the interior of the refuge;
The special CO2 absorption device can effectively adjust the CO2 adsorption rate and keep the CO2 content within a reasonable range;
Compared with the traditional filter protection method, the independent air supply system has the advantages of less maintenance, more stable and safer.
Below production process photos for reference, Find more info for your potential project.
The compressed air bottle is used as the source of breathing gas to ensure the normal breathing of internal personnel while maintaining a slight positive pressure inside, which can effectively prevent toxic gas from entering the interior of the refuge;
The special CO2 absorption device can effectively adjust the CO2 adsorption rate and keep the CO2 content within a reasonable range;
Compared with the traditional filter protection method, the independent air supply system has the advantages of less maintenance, more stable and safer.
Below production process photos for reference, Find more info for your potential project.
H2S temporary refuge is being manufactured by TLS
- Published on
Temporary refuge has the double functions as dayroom during normal operation and as Temporary Refuge (TR) in
case of emergency when flammable gas, H2S or explosion occur.
- Published on
- Published on