TLS OFFSHORE CONTAINERS & TLS ENERGY
  • Home
    • About us
    • Quality, Health, Safety and Environment
    • Manufacturing standards
    • Container certificates
  • Containerised solutions
    • Battery energy storage system (BESS) container
    • Intelligent pressurised container | MUD logging cabin
    • Laboratory container | workshop container | Equipment containers
    • Offshore accommodation cabin | office container
    • Reefer container | Refrigerated container
    • Flexible grid tied battery storage system
    • Temporary refuge shelter | Toxic gas refuge | Safe haven
    • Intelligent waste water treatment container
    • Fresh water generator container
  • Product photos & videos
  • News & Blogs
  • Contact us

TLS news & blogs

Uncompromising Quality: The 4 Essential Tests Every TLS Special Container Must Pass Before Delivery

9/28/2025

 
Before a TLS special container leaves the facility, it undergoes a meticulous gauntlet of inspections. This rigorous pre-delivery testing isn't just about compliance—it’s about guaranteeing structural integrity, safety, and longevity in the world’s most demanding environments.

Understanding these essential checks is key to knowing you're investing in reliable, high-performance equipment. Here is an in-depth look at the container pre-delivery tests that make TLS containers worthy of your trust.
 
1. The Welding Test: Guaranteeing Core Strength
The foundation of any container's reliability is its structure, and the strength of the welds is non-negotiable. The Welding Test is critical for ensuring the container’s structural stability. It verifies the quality and strength of every joint to prevent catastrophic failures.

Purpose and Method: This test aims to confirm the quality of all welded joints and detect internal defects like porosity or weak connections. We use Visual Inspection for surface flaws like cracks, and Non-Destructive Testing (NDT), which includes advanced techniques like ultrasonic, X-ray, or magnetic particle testing, to find hidden flaws.

When It Happens: Conducted immediately after the welding process is complete. Any defects must be addressed before assembly to save time and cost.
 
2. The Lifting Test: Assessing Load Resilience
A container must be able to handle the extreme forces applied during loading, unloading, and transit. The Lifting Test evaluates the container’s response to these stresses, ensuring its stability and the integrity of the critical lifting points.

Purpose and Method: The goal is to ensure the container can safely handle its designed load and unexpected stress during transportation. We perform a Load Test by applying forces that exceed the rated capacity to simulate worst-case scenarios. Crucially, a Lifting Point Check verifies the strength of the lifting ears against international safety standards.

When It Happens: This check is performed after structural welding and assembly but before applying any surface treatments, as the raw structure needs to prove its strength first.
 
3. The Watertightness Test: Protecting Your Investment
Cargo protection is paramount. The Watertightness Test is essential to confirm the container’s resilience against environmental factors—specifically water intrusion from rain, snow, or humidity.

Purpose and Method: This test checks the sealing capability against external moisture. We use a Rain Test, utilizing high-pressure water jets or simulated heavy rainfall to check for leaks. A focused Seal Check examines critical areas like door seals, welded seams, and joints to ensure they meet stringent water resistance standards.

When It Happens: The test is conducted after door seals are installed and welding is complete, but typically before final surface treatments, which allows easier identification and repair of any leakage points.
 
4. The Paint Test: Durability Meets Presentation
The external coating is more than just aesthetics; it's the container's first line of defense against corrosion and environmental damage. The Paint Test ensures the longevity and visual quality of the surface coating.

Purpose and Method: This test focuses on the coating's durability, adhesion, and appearance. We use an Adhesion Test (such as cross-cut or pull-off methods) to verify the paint’s bond to the container surface, ensuring it won't peel or flake. Film Thickness Measurement is taken with specialized gauges, as proper film thickness is essential for long-term protective quality. Finally, a thorough Visual Inspection checks for uniformity, bubbles, cracks, or peeling.

When It Happens: This test is performed after the painting process is complete to validate the container’s visual and protective qualities.
 
The Rigorous TLS Test Sequence: A Step-by-Step Guarantee
To maximize efficiency and quality assurance, TLS follows a precise, integrated inspection flow:
Welding Test→Watertightness Test (Preliminary)→Lifting Test→Surface Treatment & Painting→Watertightness Test (Final)

Only after successfully passing all these checks is the container accepted and prepared for delivery. This commitment to quality is what guarantees performance you can rely on for your most demanding applications.

TLS Offshore Containers / TLS Energy is a global supplier of standard and customised containerised solutions. 
Wherever you are in the world, TLS can help you. Please contact us.
 
​
Keywords: #TLS special containers, #Container pre-delivery tests, #Special container quality assurance, #Container welding test NDT, #ISO container lifting test, #Container watertightness test methods, #Container paint adhesion testing, #Industrial container structural integrity, #Custom container inspection process, #Pre-shipment container testing sequence

Written by Oliver



Comments are closed.

    Archives

    November 2025
    October 2025
    September 2025
    August 2025
    July 2025
    June 2025
    May 2025
    April 2025
    March 2025
    February 2025
    January 2025
    December 2024
    November 2024
    October 2024
    September 2024
    August 2024
    July 2024
    June 2024
    May 2024
    April 2024
    March 2024
    February 2024
    January 2024
    December 2023
    November 2023
    October 2023
    September 2023
    August 2023
    July 2023
    June 2023
    May 2023
    April 2023
    March 2023
    February 2023
    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    February 2022
    January 2022
    December 2021
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    July 2020
    June 2020
    November 2019
    October 2019
    September 2019
    July 2019
    June 2019
    May 2019
    February 2019
    October 2018
    September 2018
    August 2018
    June 2017
    June 2016
    June 2015
    June 2014
    December 2013

    Categories

    All
    A60
    Accommodation Cabin
    ADNOC
    Age System65288bess
    Commercial And Industrial & Microgrid Energy Storage System
    Container Accessories
    Container Standards
    Container Test
    CUTTING SKIPS
    Drop Test
    Dry Container
    ESS Container
    FEA
    Feedback From Clients
    FREEZER
    Iso Container
    Laboratory Container
    LIFTING TEST
    MCC Shelter
    |MWD/LWD Cabin
    NEGATIVE PRESSURE
    Offshore Accommodation Module
    Offshore Living Quarter
    Offshore Tank
    Offshore Workshop Container
    POSITIVE PRESSURE
    Pressurised Container
    PROCESS OF CONTAINER
    Reefer Container
    Refrigerated
    Refrigerated Container
    SEWAGE TREATMENT
    Temperature Control
    Temporary Refuge
    Temporary Refuge (TR) Shelter
    TLS OFFSHORE CONTAINER
    WATER TIGHTNESS
    WELDING INSPECTION
    Workshop Container

Featured products
​Battery energy storage system (BESS) container
​
Intelligent pressurised container/MWD cabins
Offshore laboratory container, Workshop container
Offshore ccommodation container
Offshore reefer container
​
​Temporary refuge (TR) shelter, toxic gas refuge (TGR)​

Company
About us

News & Blogs
Product photos & videos
Privacy policies
​Terms and conditions
Contact us
Communities
Facebook
​Twitter
Linkedin
Instagram
​Pinterest
​Flickr
Contact us
Email: [email protected]
Hotline: +65-89601885; +65-31386967; ​
All Rights Reserved 2020 © TLS Offshore Containers / TLS Energy
  • Home
    • About us
    • Quality, Health, Safety and Environment
    • Manufacturing standards
    • Container certificates
  • Containerised solutions
    • Battery energy storage system (BESS) container
    • Intelligent pressurised container | MUD logging cabin
    • Laboratory container | workshop container | Equipment containers
    • Offshore accommodation cabin | office container
    • Reefer container | Refrigerated container
    • Flexible grid tied battery storage system
    • Temporary refuge shelter | Toxic gas refuge | Safe haven
    • Intelligent waste water treatment container
    • Fresh water generator container
  • Product photos & videos
  • News & Blogs
  • Contact us