The lab containers are fully insulated suitable for operation in all extremes of climatic conditions. The laboratory operating area in negative pressure is air conditioned with extracted air filtered and returned to maintain a comfortable working environment and to reduce operating costs.
Applications for the laboratories can be fully operational within hours of arriving on site. So it can be used on exploration projects for the primary sizing of samples or as an on-site mining laboratory potentially saving millions in analysis and setup costs.
Specification:
• All units are designed, manufactured and certified to the latest DNV 2.7-1 and EN 12079 Offshore Container Standard and or ATEX, IEC and / or SOLAS standards
• Built for Safe Area or Hazardous Area Operation Zone 1 and Zone 2
• Pressurised Control Module / Cabin create a safe area environment for personnel and equipment, with built in HVAC and power control systems.
• All modules are designed, built and completely fitted out as per customer's specifications and requirements
• A60 Fire Rating complete with Certificate
• Units designed and built complete with Fire & Gas Detection System, HVAC System and Communication System
• Factory Acceptance Test and Pre-commissioning for all electrical and instrumentation
Please download laboratory container brochure for reference.
Applications for the laboratories can be fully operational within hours of arriving on site. So it can be used on exploration projects for the primary sizing of samples or as an on-site mining laboratory potentially saving millions in analysis and setup costs.
Specification:
• All units are designed, manufactured and certified to the latest DNV 2.7-1 and EN 12079 Offshore Container Standard and or ATEX, IEC and / or SOLAS standards
• Built for Safe Area or Hazardous Area Operation Zone 1 and Zone 2
• Pressurised Control Module / Cabin create a safe area environment for personnel and equipment, with built in HVAC and power control systems.
• All modules are designed, built and completely fitted out as per customer's specifications and requirements
• A60 Fire Rating complete with Certificate
• Units designed and built complete with Fire & Gas Detection System, HVAC System and Communication System
• Factory Acceptance Test and Pre-commissioning for all electrical and instrumentation
Please download laboratory container brochure for reference.
Main structure:
Mainly divided into two categories
1. Important and non-redundant primary structures, which are the basic components that transfer the resultant load of the cargo to the crane hook or forklift (i.e. form the transfer path from the payload to the sling load), include at least: Top and bottom side beams, top and bottom end beams, corner posts, lifting lugs, fork grooves
2. Non-basic main structure. Examples include floors and other components with major functions other than those described for basic components. Baffles, stacking corners and end plates on hollow sections fall into this category. In addition non-essential primary structures also include protective framing members.
Secondary structure
The non-loaded parts that do not need to be considered in design calculations are called secondary structures, including
1. Door, wall and roof panels, non-slip cover
2. Reinforced plate and corrugated plate
3. Parts used only to protect tank structure
4. Internal fixed points
TLS is an international supplier that can customize onshore | offshore special containerised solutions,Any requirements, please contact us directly:
E-mail: sales@tls-containers.com
Hotline: +65-65637288; +65-31386967
Mainly divided into two categories
1. Important and non-redundant primary structures, which are the basic components that transfer the resultant load of the cargo to the crane hook or forklift (i.e. form the transfer path from the payload to the sling load), include at least: Top and bottom side beams, top and bottom end beams, corner posts, lifting lugs, fork grooves
2. Non-basic main structure. Examples include floors and other components with major functions other than those described for basic components. Baffles, stacking corners and end plates on hollow sections fall into this category. In addition non-essential primary structures also include protective framing members.
Secondary structure
The non-loaded parts that do not need to be considered in design calculations are called secondary structures, including
1. Door, wall and roof panels, non-slip cover
2. Reinforced plate and corrugated plate
3. Parts used only to protect tank structure
4. Internal fixed points
TLS is an international supplier that can customize onshore | offshore special containerised solutions,Any requirements, please contact us directly:
E-mail: sales@tls-containers.com
Hotline: +65-65637288; +65-31386967
The ventilation part of the positive pressure explosion-proof container mainly includes the cooling and heating system of the fan for air supply and ventilation, indoor air conditioning, and heater. In the container, the air is supplied from a long distance by a centrifugal exhaust fan to finally achieve the purpose of indoor positive pressure.
Refrigeration/Heating: Choose split air conditioners for explosive gas atmospheres. The ambient temperature is -7°C~43°C, and 80% of the working conditions are widely used in hazardous environments such as oil exploration and refining, as well as offshore oil platforms. The internal unit can choose not to be explosion-proof, and foreigners must have the overall explosion-proof certification of the explosion-proof organization.
Air supply fan: The booster fan will choose a centrifugal explosion-proof fan. When the booster system is activated, the fan will always work, so the protective gas can continuously replace the original air in the room, so as to ensure the safety of the container. In order to monitor the air exchange rate, a flow sensor is installed at the air outlet.
As a new container product in recent years, the positive pressure explosion-proof container still needs to accumulate technical strength. It has great prospects in the future container market and because it is a high-level service container, its added value is very high
Refrigeration/Heating: Choose split air conditioners for explosive gas atmospheres. The ambient temperature is -7°C~43°C, and 80% of the working conditions are widely used in hazardous environments such as oil exploration and refining, as well as offshore oil platforms. The internal unit can choose not to be explosion-proof, and foreigners must have the overall explosion-proof certification of the explosion-proof organization.
Air supply fan: The booster fan will choose a centrifugal explosion-proof fan. When the booster system is activated, the fan will always work, so the protective gas can continuously replace the original air in the room, so as to ensure the safety of the container. In order to monitor the air exchange rate, a flow sensor is installed at the air outlet.
As a new container product in recent years, the positive pressure explosion-proof container still needs to accumulate technical strength. It has great prospects in the future container market and because it is a high-level service container, its added value is very high