What is negative pressure?
When the exhaust air volume in the space is greater than the air intake volume, the space is in a negative pressure state, the air outside flows into the interior and is discharged through the exhaust outlet for centralized treatment.

When to choose negative pressure?
When the external environment is safe, but toxic and harmful gases are generated inside, negative pressure is preferred.
  • Modular Petroleum Laboratory
  • Laboratory container / cabin
  • Blast Resistant Container, Blast proof Container
  • Mud Lab
 
NEGATIVELY PRESSURISED CONTAINERS PROVIDED BY TLS
  • DNV2.7-1 / EN12079 certification
  • CSC plated
  • A0 or A60 fire rating
  • Autonomous fire, gas and smoke detection system.
  • Self‐contained Heat, Ventilation and Air Conditioning (HVAC) system, with fast-plug connection to rig power supply system
  • Water supply system with connections to rig supply system
  • Air Pipeline connected with air gun 
  • Negative pressure inside
  • Explosion proof fume hood
  • Acid and alkali resistant anti-static workbench
  • Area Network (LAN) access.
  • Working and storage furnitures
  • Anti-slip flooring
  • Ex light, switch, socket, cabling
  • Quick and easy hook up to on-board services
  • Designed for easy stacking
  • Compliant with ATEX, IECEx standard on request.
  • 10ft, 20ft, or customised dimension according to requirement
This is a positive pressure explosion-proof, fire grade A60 laboratory container, which can be used from -25 ℃ to +50℃, with good sealing, rain resistance, sand resistance, suitable for land oil exploration and offshore oil exploration in hazardous areas and desert areas. The design and construction meet the IEC60079-13 2010 specification, DNV2.7-1 and SOLAS 2009. Explosion-proof appliances meet the CNEX or ATEX explosion-proof standards.

The positive pressure test container is integrated with CPFG control cabinet, positive pressure air path system, explosion-proof centrifugal air unit, safe power supply system, fire alarm system, lighting system, alarm system, explosion-proof air conditioner, air valve control system and explosion-proof isolation switch box.

In order to meet the various conditions for the products to be used in Petrobras, TLS insists on strictly controlling the quality of the products in every step, from preprocessing of sheet and section steel to welding and assembly, from painting and decoration to debugging and installation, from label and decal to cleaning and packing. In addition to professional certification certificates, professional detection methods, real and convincing data and several measured operation results are the quality assurance that TLS believes should be provided to customers.

TLS is an international company that can customize onshore | offshore special containers for you.
Any requirements, please contact us directly:
E-mail: sales@tls-containers.com
Hotline: +65-65637288; +65-31386967
Key words:
#Petrobras  #brazil #oil & #offshore standard  #brazil oil  #pressurised container  #laboratory container  ​#IEC60079-13 #DNV2.7-1 #CNEX  #TLS offshore containers
CPFG is divided into three working modes: manual mode, bypass mode and automatic mode. Turn the mode selector switch to the corresponding mode, at the same time, HMI face change will switch to the corresponding mode. The operation instructions of each mode are as follows:
 
Manual mode: only for emergency use, only the HMI "STOP" button/ESD signal/Cut-off signal can stop the output of safety power supply.
Bypass mode: Only can be used in safe area, make sure no dangerous gas and fire alarm start the safety power supply.
Auto mode: Can be used for normal use in dangerous area.

​Any requirements, please contact us directly:
E-mail: sales@tls-containers.com 
Hotline: +65-65637288; +65-31386967
Key words:
# CPFG  # ESD  # Manual mode  # Bypass mode  # Auto mode   #A60 fire rating  #explosion-proof  #LAB # workshop container  #TLS offshore containers  #laboratory containe