​Motor control center (MCC) shelters consist of single or multiple electrical units, which are combined to meet larger application needs. These components allow engineers to control electric motors from a central location, such as a mechanical or electrical room.
MCCs are typically found in large commercial or industrial buildings and typically contain motor starters, circuit breakers, programmable controllers, metering devices, etc. MCCs may be used in any facility that operates a large number of electric motors.
There is always the possibility or risk of fire or explosion when MCCs are used in, around or near flammable gases or vapors, flammable liquids, flammable dust, flammable fibers or droplets.
The MCC shelter provided by TLS integrates sensors, fire and gas systems, intelligent PLC, fire dampers, air conditioners, etc. in a positive pressure container environment, which helps isolate the control systems in the MCC shelter from the external hazardous environment and facilitates the operation of surrounding systems. Increase the safety factor of the construction environment.
The MCC shelter provided by TLS can meet DNV2.7-1| EN12079, pass third-party certification such as CCS and BV, and can be customized according to customer‘s requirements, which can also be used for Power control centre (PCC), Variable speed driver (VSD), Variable Frequency Drive (VFD) shelter. 
​Any requirements, please contact us directly:
E-mail: sales@tls-containers.com 
Hotline: +65-65637288; +65-31386967
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurisation;
– located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation;
– located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation;
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurisation and artificial ventilation.

TLS offshore contaienrs international collaborates with the third parties (BV, DNV, CCS) to do the site inspection for the pressurised containers according to IEC60079-13 for our international clients. 
  • MUD logging unit | mud logging cabin (Download offshore pressurised mud logging cabin brochure for reference)
  • MWD cabin / LWD cabin
  • ROV control cabin / container
  • Pressurised Living quarters / accommodation cabin
  • Office cabin (positively pressurised)
  • Storage cabin | Workshop cabin
  • Operating room | control cabin
  • Laboratory cabin​ (Negatively pressurised or positively pressurised, Ex-proof)
  • Telecommunication cabin
  • Pressurised engine cabin | enclosure in hazardous zones (zone 1 or zone 2)
  • ​ATEX pressurized container, Ex-proof cabin | enclosure
  • Motor control centre (MCC) pressurized shelter | MCC enclosure
  • Power control centre (PCC) pressurized shelter | enclosure | container
  • Variable speed driver (VSD) pressurized shelter | enclosure | container
  • Switchgear pressurized enclosure | container
  • Variable Frequency Drive (VFD) pressurized shelter | enclosure / container
  • Diesel generator (DG) set container | pressurised DG enclosure for the usage in hazardous zones
TLS adheres to strict quality control and continuous innovation. After more than 30 years of development, the products involve numbers of industries and product types.
​