MWD CABIN, MUD LOGGING CABIN, PRESSURISED CONTAINER
Download offshore pressurised mud logging cabin brochure for reference.
• All units are designed, manufactured and certified to the latest DNV 2.7-1 and EN 12079 Offshore Container Standard and/ or DNV 2.7-2 Offshore Service Modules Standard, ABS Rules, ATEX, IEC and/ or SOLAS standards
• Built for Safe Area or Hazardous Area Operation - Zone 1 and Zone 2
• Pressurised Control Module/ Cabin create a safe area environment for personnel and equipment, with built in HVAC and power control systems.
• All modules are designed, built and completely fitted out as per customer's specifications and requirements
• A60 Fire Rating complete with Certificate
• Units designed and built complete with Fire & Gas Detection System, HVAC System and Communication System
• Factory Acceptance Test and Pre-commissioning for all electrical and instrumentation
Download offshore pressurised mud logging cabin brochure for reference.
• All units are designed, manufactured and certified to the latest DNV 2.7-1 and EN 12079 Offshore Container Standard and/ or DNV 2.7-2 Offshore Service Modules Standard, ABS Rules, ATEX, IEC and/ or SOLAS standards
• Built for Safe Area or Hazardous Area Operation - Zone 1 and Zone 2
• Pressurised Control Module/ Cabin create a safe area environment for personnel and equipment, with built in HVAC and power control systems.
• All modules are designed, built and completely fitted out as per customer's specifications and requirements
• A60 Fire Rating complete with Certificate
• Units designed and built complete with Fire & Gas Detection System, HVAC System and Communication System
• Factory Acceptance Test and Pre-commissioning for all electrical and instrumentation
A motor control center (MCC) is an assembly to control some or all electric motors in a central location. It consists of multiple enclosed sections having a common power bus and with each section containing a combination starter, which in turn consists of motor starter, fuses or circuit breaker, and power disconnect. A motor control center can also include push buttons, indicator lights, variable-frequency drives, programmable logic controllers, and metering equipment. It may be combined with the electrical service entrance for the building.
MCC's are typically found in large commercial or industrial buildings where there are many electric motors that need to be controlled from a central location, such as a mechanical room or electrical room.
A motor control center panel (MCC Panel) is an assembly of one or more enclosed sections having a common power bus and principally containing motor control units. As those electric elements inside MCC panels are not EX approved, In some conditions, such as hazardous zones in FPSO, MCC panels have to be put in pressurised enclosure / containers for safely work. Pressurised containers are composed of CPFG, fire & gas detectors, pressurised blower fan, pressure difference gauge, control panels, etc. which will create a positive pressure working environment inside for the MCC panels by blowing fresh air when the MCC panels are installed inside. TLS offshore containers international is a professional containerised solution provider with tens of years’ experience in this area. TLS teams are eager to give professional support to worldwide clients by providing premium quality containerised solutions.
Please contact us sales@tls-containers.com for more information.
MCC's are typically found in large commercial or industrial buildings where there are many electric motors that need to be controlled from a central location, such as a mechanical room or electrical room.
A motor control center panel (MCC Panel) is an assembly of one or more enclosed sections having a common power bus and principally containing motor control units. As those electric elements inside MCC panels are not EX approved, In some conditions, such as hazardous zones in FPSO, MCC panels have to be put in pressurised enclosure / containers for safely work. Pressurised containers are composed of CPFG, fire & gas detectors, pressurised blower fan, pressure difference gauge, control panels, etc. which will create a positive pressure working environment inside for the MCC panels by blowing fresh air when the MCC panels are installed inside. TLS offshore containers international is a professional containerised solution provider with tens of years’ experience in this area. TLS teams are eager to give professional support to worldwide clients by providing premium quality containerised solutions.
Please contact us sales@tls-containers.com for more information.
Temporary refuge definition
The temporary refuge (TR) is a safe and sealed area for the people protection during environmental contamination from poisonous gases which can be present in operating areas where oil and/or gas research, extraction and pre-production are performed. This contamination could be related to the escape of gas from drilling wells, from piping or storage / production facilities or to the production of toxic gases due to an explosion in the surrounding area.
The environmental conditions inside TR are constantly monitored to avoid the presence of contaminated air.
The TR facility needs to be designed with the following minimal characteristics:
This is achieved inside the sealed TR. Area as follow:
The following equipment are installed inside TR:
To maintain the correct required oxygen ration and to prevent the increase of carbon dioxide ratio inside TR, a reserve of breathable air and oxygen and a CO2 reduction system are installed inside the TR.
The TR consists in:
TR will be equipped with the following safety systems:
More information about TR shelter, TGR
Don’t hesitate to contact us for more information about the temporary refuge shelter and toxic gas refuge. We are eager to explain the possibilities for your applications.
The temporary refuge (TR) is a safe and sealed area for the people protection during environmental contamination from poisonous gases which can be present in operating areas where oil and/or gas research, extraction and pre-production are performed. This contamination could be related to the escape of gas from drilling wells, from piping or storage / production facilities or to the production of toxic gases due to an explosion in the surrounding area.
The environmental conditions inside TR are constantly monitored to avoid the presence of contaminated air.
The TR facility needs to be designed with the following minimal characteristics:
- Have an area sealed from external air infiltrations
- Have a structure able to resist to nearby explosions without losing integrity and tightness.
- Have the capacity to assure the breathability of air inside protected area for a defined time needed to keep safe all personnel on board until the arrival of rescue transportation or until the return of external air to a safe condition.
This is achieved inside the sealed TR. Area as follow:
- Fully recirculated air conditioning system
- Safe area in overpressure respect to the external
- Entrance in the safe area protected by airlocks
The following equipment are installed inside TR:
- A reserve of breathable air
- A reserve of oxygen
- A CO2 reduction system
To maintain the correct required oxygen ration and to prevent the increase of carbon dioxide ratio inside TR, a reserve of breathable air and oxygen and a CO2 reduction system are installed inside the TR.
The TR consists in:
- A large area able to contain the POB, the minimum area will need to be of 1.5 sqm per person
- Two or more airlocks equipped with air washing systems and interlocked doors
- A fully recirculated air conditioning system area
- A medical area
TR will be equipped with the following safety systems:
- TR control/command panel including gas level monitoring console and the residual levels of air and oxygen in the air/oxygen bottles of the TR system
- ESD/F&G console unit: emergency shut-down and fire & gas console
- Smoke detectors
- Fire detectors
- Gas detectors
- PA/GA access point
- Telephone access point
- Communication point into each air-lock
- CCTV system