What is DNV certification?
DNV (Det Norske Veritas), a Norwegian classification society, merged with Germanischer Lloyd (GL) in September 2013 to form the world's largest classification society DNV GL Group.
 As a classification society, DNV GL sets standards for the offshore, maritime, energy and oil and gas industries. The purpose of these standards is to provide users, operators and engineers with requirements, principles and acceptance criteria.

Two common standards are:
  • DNVGL-ST-E271, Offshore containers (2.7-1)
  • DNVGL-ST-E273, Portable offshore containers (2.7-3)
 
DNV2.7-1 and DNV2.7-3 in common
  • Both 2.7-1 and 2.7-3 are standards specify requirements and recommended practice covering transport of offshore containers and portable offshore containers.
  • The standards cover the specific areas of design, manufacturing, testing, certification, and periodic inspection
  • Both standards cover the lifting frames or containers and, in most cases, not the equipment contained within the frames
  • Both standards cover the safe lifting and handling of offshore containers and installations between two floating vessels and between vessels and fixed or floating offshore installations.
 
Difference between DNV2.7-1 and DNV2.7-3
Apart from the difference in standard details, the biggest difference is that the maximum gross weight (MGW) of dnV2.7-1 certified container is less than 25,000 kgs, and the MGW of DNV2.7-3 certified container is greater than 25,000 kgs.
 
Although DNV2.7-1 and DNV2.7-3 standards are set by DNV Classification Society, they are also recognized by other classification societies (BV, LRs, etc), which will issue corresponding certificates according to the same standards.
Make a preliminary judgment based on the following:
Do your containers need to be placed in hazardous areas (ZONE1, ZONE 2)?
  • Yes, containers need to be placed in hazardous areas.
  • You need an explosion-proof container.
a) If the equipment in the container is explosion-proof, you can choose a container with explosion-proof and A60 fireproof function only
b) If the equipment in the container is non-explosion-proof, you need to choose an A60 fireproof and explosion-proof positively pressurized container (the air supply volume is greater than the exhaust volume. The indoor air is in a positive pressure state. Combined with the air conditioning unit, the cleanliness of the air sent into the container can be guaranteed.)

the air supply volume is less than the exhaust air volume, and the main cabin is in a negative pressure state. The surrounding air flows into the space and is discharged through the exhaust port for unified treatment.

  • No, both inside and outside the container are safe areas
  • You can choose a non-explosion proof container.
You can request whether the container has fire protection requirements according to your own needs. In general, the container can meet the A60 fire protection standard. At this time, the container is equipped with the corresponding fire damper (when a fire occurs, the fire damper can be automatically closed to cut off the spread of the fire through the ventilation duct, suitable for ships, offshore platforms and underground Engineering and other humid environments)​
Key words:
#DNV  #BV  #LR    #ABS  #SGS  #DNV2.7-1  #A60 fire rating  #explosion-proof  #LAB # workshop container  #TLS offshore containers #ZONE0 #ZONE1 #ZONE 2
This is a positive pressure explosion-proof, fire grade A60 laboratory container, which can be used from -25 ℃ to +50℃, with good sealing, rain resistance, sand resistance, suitable for land oil exploration and offshore oil exploration in hazardous areas and desert areas. The design and construction meet the IEC60079-13 2010 specification, DNV2.7-1 and SOLAS 2009. Explosion-proof appliances meet the CNEX or ATEX explosion-proof standards.

The positive pressure test container is integrated with CPFG control cabinet, positive pressure air path system, explosion-proof centrifugal air unit, safe power supply system, fire alarm system, lighting system, alarm system, explosion-proof air conditioner, air valve control system and explosion-proof isolation switch box.

In order to meet the various conditions for the products to be used in Petrobras, TLS insists on strictly controlling the quality of the products in every step, from preprocessing of sheet and section steel to welding and assembly, from painting and decoration to debugging and installation, from label and decal to cleaning and packing. In addition to professional certification certificates, professional detection methods, real and convincing data and several measured operation results are the quality assurance that TLS believes should be provided to customers.