Solar system with battery backup​ is mainly composed of four parts, including Battery System (BS), Power Conversion System (PCS), Battery Management System (BMS), and Monitoring System; at the same time, in practical application, for the convenience of design, management and Meanwhile, in practical applications, the BS, PCS and BMS are usually recombined into modular BESS for easy design, management and control, while the monitoring system is mainly used to monitor, manage and control one or more modular BESS.
  • The battery system is the main carrier of BESS to store and release electrical energy, and its capacity and operation status are directly related to the energy conversion capacity and safety reliability of BESS.
  • The PCS is a device consisting of power electronic conversion devices that connects the battery system to the AC grid and is a key component of the energy exchange between the BESS and the outside world.
  • BMS is a real-time monitoring system composed of electronic circuit equipment, which can effectively monitor various states of the battery system (voltage, current, temperature, charge state, health state, etc.), safely manage the charging and discharging process of the battery system (such as preventing overcharging and over-discharging management), alarm and emergency protection treatment of possible battery system faults, and optimize the control of battery system operation, and ensure safe, reliable and stable operation of the battery system
structure diagram of solar battery storage systems
​Motor control center (MCC) shelters consist of single or multiple electrical units, which are combined to meet larger application needs. These components allow engineers to control electric motors from a central location, such as a mechanical or electrical room.
MCCs are typically found in large commercial or industrial buildings and typically contain motor starters, circuit breakers, programmable controllers, metering devices, etc. MCCs may be used in any facility that operates a large number of electric motors.
There is always the possibility or risk of fire or explosion when MCCs are used in, around or near flammable gases or vapors, flammable liquids, flammable dust, flammable fibers or droplets.
The MCC shelter provided by TLS integrates sensors, fire and gas systems, intelligent PLC, fire dampers, air conditioners, etc. in a positive pressure container environment, which helps isolate the control systems in the MCC shelter from the external hazardous environment and facilitates the operation of surrounding systems. Increase the safety factor of the construction environment.
The MCC shelter provided by TLS can meet DNV2.7-1| EN12079, pass third-party certification such as CCS and BV, and can be customized according to customer‘s requirements, which can also be used for Power control centre (PCC), Variable speed driver (VSD), Variable Frequency Drive (VFD) shelter. 
​Any requirements, please contact us directly:
E-mail: sales@tls-containers.com 
Hotline: +65-65637288; +65-31386967
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurisation;
– located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation;
– located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation;
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurisation and artificial ventilation.

TLS offshore contaienrs international collaborates with the third parties (BV, DNV, CCS) to do the site inspection for the pressurised containers according to IEC60079-13 for our international clients.