Land-based oil exploration and offshore platform oil exploration areas have the potential to produce explosive gases, and for areas where fires and explosions may occur are known as hazardous areas and are generally divided into three zones - Zone 0, Zone 1, and Zone 2.  Modern drilling and exploration sites require strict explosion-proof performance of the equipment on site, so TLS provides the perfect solution with positive pressure explosion-proof containers 
 
The principle of the positive pressure explosion-proof container is to achieve explosion-proof technical requirements through the container shell, so that all the regular non-explosion-proof machinery installed in the container achieve the purpose of explosion-proof.
 
The positive pressure ventilation system ​ is the key to making the container explosion-proof. When the total power supply is turned on, firstly the system automatically turns on the explosion-proof blast system. The explosion-proof centrifugal fan extracts fresh air from 30 meters outside the danger zone into the positive pressure container. The air in the positive pressure container is purged and a positive pressure of more than 50pa is established. The total power supply is automatically turned on when the control conditions are met, then the power supply can be turned on to control the power supply and turn on other electrical equipment in the positive pressure container.
 
In the process of turning on or in the operation of the equipment in the container, if the explosion-proof control system monitors the presence of dangerous gases in the container or fails to reach the corresponding positive pressure, the alarm system will alarm and warn, and if the control conditions in the container are still not met within the specified time, or if the alarm limits are reached directly, the non-explosion-proof control system in the container will be closed automatically, so as to achieve the purpose of explosion-proof.
POSITIVE PRESSURE CONTAINER
Instructions for additional equipment related to refrigeration units such as CA, MA and humidity controllers.
  • CA is short for Controlled Atmosphere.  It is an auxiliary facility that controls the levels of CO2 and O2 in the container.  The container should be airtight and have a nitrogen generator and source of carbon dioxide (such as a carbon dioxide compressed air bottle or scrubber). In both cases, the oxygen content is controlled by ventilation.
  • MA stands for Modified Atmosphere.  This means that the container has an interface into which the mixed gas is injected before shipping.  During transport, the air composition in the container is no longer controlled.
  • Humidifier can use a water source or condensate from an evaporator to humidify the circulating air. Dehumidification can be achieved by evaporative heating devices or chemical reactions. The humidity inside the chamber can only be adequately controlled if both dehumidification and humidification are available.
Refrigerated container
TLS is an international supplier that can customize onshore | offshore special containerised solutions,Any requirements, please contact us directly:
E-mail: sales@tls-containers.com
Hotline: +65-65637288; +65-31386967
Offshore containers should be inspected regularly every year. Regular inspections should be performed on the inside and outside of the container when it is empty. TLS has prepared tips for you to check including:
  1. Inspection of signs and nameplates.
  2.  Weld inspection of main structural members to confirm that there are no visible defects.
  3.  Inspection of lifting lugs and lashing points for deformation, mechanical damage, or other dangerous defects.
  4.  Inspect all structures for corrosion, deformation, mechanical damage, or other dangerous defects.
  5. Check the condition of the container floor, including the bottom drainage facilities and drainage holes.
  6.  Check for corrosion and mechanical damage inside the fork pockets (where applicable).
  7. Check the door, frame, seal, hinge, door lock, etc., and confirm the opening and closing of the door.
shipping container Maintenance