1. Reserved openings for energy storage containers: the common sizes of containers are 40ft and 20ft, and they can also be customized according to customer needs. The fire protection system of energy storage containers is a separate system, including smoke detectors and temperature detectors. , gas fire extinguishing control panel, emergency start, stop button, gas proof indicator and other components, all of which need to be reserved openings, especially the openings for pressure relief ports, which must be designed before the container is integrated. It will cause water leakage and bring security risks to the electrical system, and the fire protection system will also increase the risk of not spraying due to short circuit.
2. Gas fire extinguishing device: The location selection and fixing method of the fire extinguishing device are the key points. The container is relatively long and narrow. If only the fire extinguishing device is placed in the corner and no release pipeline is arranged, it will be difficult for the agent to reach the other end of the container, and it is difficult to achieve an effective fire extinguishing effect, especially for a 40ft container. For the fixed method, the reinforcement method should be considered in the early stage, rather than the temporary solution of the fire extinguishing device, which will cause a lot of rework and hidden dangers. 3. Rainproof problem: When the container battery energy storage is placed in the open air, the outdoor alarm device should be rainproof or ordinary rainproof measures should be used. Either way, it is fine. This is very important, otherwise the fire alarm system will be corroded or short-circuit and do not spray as mentioned in the first item. 4. Power-cutting problem: the non-fire-fighting power in the containerized energy storage system generally includes air conditioning or fresh air system, lighting, etc. When the smoke and temperature senses act at the same time, the power supply is cut off. This needs to be considered in the early design. At the same time, pay attention to the reasonable arrangement of the wiring of these systems and the wiring of the fire extinguishing device, so as not to be confused, so as to avoid interference and false alarms or false sprays. As drilling has become more complex, logging has had to adapt and improve as the number of horizontal and directional wells drilled has increased. Measurement with drilling (or MWD) is a type of logging that combines a measurement tool into the drill column and provides real-time information to help with steering the drill. When drilling quite precise wells, MWD can provide drilling engineers with real-time information to make important decisions while drilling. Due to the environmental factors in the exploration area, TLS can provide MWD cabin to ensure that MWD work is carried out safely and effectively. To provide a safe and healthy working environment, the TLS MDW cabin has the following standard specifications:
Offshore shipping containers are widely used for the transportation and hoisting of goods or equipment between offshore facilities and ships in harsh environments with high temperature, high humidity, and high salt spray. Therefore, there are extremely high requirements for the anti-corrosion of the surface of the offshore container. The coating process steps of TLS are as follows: 1. Preprocessing Remove the oxide scale, rust, grease, dirt, and other attachments on the surface of the exposed steel structure to ensure the anti-corrosion performance of the coating; zinc-rich primers are applied automatically on the assembly line after the steel is shot-blasted. It temporarily protects the surface of freshly shot steel, preventing it from rusting in the gaps made during the container's manufacture. 2. Shot-blasted the whole container Before painting, the surface of the weld and the heat sensitive area of the weld should be shot-blasted. The surface of the steel structure should be free of burrs, bumps, dust, dirt, no painting, sharp edges, and all rough-cut edges should be ground to a radius of at least 2mm; 3. Pre-coating Pre-coating is applied to areas that are not easy to coat, including, but not limited to, the edges of steel plates, welds, corners, bolt holes, beam edges, and other areas that are difficult to paint. 4. Spray Each coat should be applied evenly over the entire surface, and defects such as missing paint, sags, and drips must be avoided. And each coating should contain no pinholes, blisters, and leaks. 5. Drying: Speed up the curing process. TLS uses environmentally friendly water-soluble paints, and the coating operators have relevant technical certifications. TLS containers are not prone to corrosion, paint failure, fading and discoloration which can make the container work better for its use value. How does the ventilation process operate in automatic mode of our ex-proof pressurized container?10/9/2022
When the container is in automatic mode, the system will display different detection states for different detection conditions.
TLS is an international supplier that can customize onshore | offshore special containerised solutions,Any requirements, please contact us directly: E-mail: sales@tls-containers.com Hotline: +65-65637288; +65-31386967 |
Archives
April 2024
Categories
All
|